Rhapsody H-30 Holmium Laser System

Cook Incorporated

Country / region:United States (US)Submission type:Traditional

Product code GEX· 21 CFR 878.4810

View Summary PDF

Company

United States (US)

Product code

GEX
21 CFR 878.4810

Predicate devices

1

Cited as predicate

0

Device details

FDA 510(k) registration fields

K number
K172325
Device name
Rhapsody H-30 Holmium Laser System
Country / region
United States(US)
Product code
GEX
Device class
Class 2
Regulation number
21 CFR 878.4810
Date received
2017-08-01
Decision date
2017-10-26
Submission type
Traditional
Technology type
Other(AI inferred)
Clinical applications
Surgical cutting
Primary application
Surgical cutting
Classification source
AI classified

Indications for Use

The Rhapsody H-30 Holmium Laser System is intended for incision, excision, resection, ablation, vaporization, coagulation, hemostasis of soft tissue, or stone fragmentation during open surgical, laparoscopic, percutaneous or endoscopic procedures in urologic, gynecologic, gastroenterological, or pulmonary applications.

Intended Use

The Rhapsody H-30 Holmium Laser System is intended for incision, excision, resection, ablation, vaporization, coagulation, hemostasis of soft tissue, or stone fragmentation during open surgical, laparoscopic, percutaneous or endoscopic procedures in urologic, gynecologic, gastroenterological, or pulmonary applications.

Device Description

Laser Wavelength 2100 nm. Maximum Output 30 W. Repetition Rate 5 to 20 Hz. Visible Aiming Beam Variable intensity <3 mW. Minimum Energy 0.5 J at 5 Hz. Maximum Energy 3.5 J at 5 Hz. Input Voltage 115 & 230 V (full power). Detects a resistor embedded within the fiber to identify the size of the attached fiber and limit the laser energy to the fiber's maximum allowable power output. Communicates with a printed circuit board (two-way communication) embedded within the laser fiber to display extra information onscreen, or recording use information for the laser system and the fiber such as power setting, number of pulses, and error codes. Max Flash-lamp Voltage 700 V. Blast Shield User accessible. Water Reservoir Plastic. Filter De-ionized cartridge & strainer. Enclosure Metal with cabinet & flat top. Control Panel Rotatable. Water Pump Fixed with slightly different orientation. Firmware 1.5 version 1.6 version.